APC150
- Pneumatic version presussure range -90 to 1000 Kpa
- Vacuum to -99.9 with optional external vacuum pump
- Portable type
- Reduce calibration time 40%
- Accuration 0.025% FS (optional 0.01% FS)
- Control Stabillity 0.01%
- FS Include PC Calibration Software
- Execute 10 Points Test on a 2000 kpa Transmitter in Minutes!!!
- Engineering Unit: kPa, Psi, Kg/cm2,Bar, Mpa (depend on range)
- Pressure connection: 1/8†and 1/4†NPT Female
- Electrical Input: 4-20 Milli-amp with 24 Vdc Loop Power.
APC300
- Pneumatic version presussure range -90 to 2000 Kpa
- Reduce calibration time 40%
- Accuration 0.025% FS (optional 0.01% FS)
- Control Stabillity 0.01% FS
- Execute 10 Points Test on a 2000 kpa Transmitter in Minutes!!!
- Engineering unit: Psi, Kpa, Kg/cm², Bar, mmH2O
- Pressure Connection: 1/8″ and 1/4″ NPT Female
- Medial Compatibility: Clean Dry Air
- Electrical input: 4-20 Milli-amp with Loop Power
AHC Series
- Hydraulic version pressure range up to 1000 bar
- Warm up time 10 minute
- Reduce calibration time 40%
- Accuration 0.05% FS (optional 0.025% FS or 0.01% FS 1 year)
- Engineering unit : Psi, Kpa, Mpa, Kg/cm2, Bar
- Pressure Connection: 1/2″ and 1/4″ or 3/8″ NPT Female
- Electrical input: 4-20 Milli-amp with Loop Power
- Execute 20 Points Test on a 1000 Bar Transmitter in Minutes!!!
HPC Series
- Hydraulic version pressure range up to 700 bar or 10000 psi
- Optional Digital Gauge Range: 100, 300, 500, 1000, 2000, 3000, 5000, 10000 psig
- Pressure Connection: 1/4″, 3/8″, 1/2″ BSP Female
- Medial Compatibility: Hydraulic Oil or or Distilled water
- Material: Brass, Nickel Plated
- Unit Size: 320x300x250 mm
- Weight: 9 kg
Digital Pressure Gauge
- Material : 316 SS
- Accuracy : ±0.05% FS Positive pressure, Vacuum/500 psi & below
- Dimensions 4.375†x 5.0†x 1.50â€Â
- Bottom Connection ¼†male NPT
- Display 5 Digit, 0.65â€Â, Bargraph -0 to 100% in 20 segments
- Power 3 size AA alkaline batteries life 1500 hour w/o backlight
- Enclosure : NEMA 4, IP65, CSA Intrisically safe Clas 1 Div. 1.
Hand Pump
- Material : 316 SS
- Hydraulic Pump 0 to 5000 psi
- Pneumatic Pump -12.3 to 500 psi
Test Bench WKS Series
- Pneumatic / Electrical Test Bench
- Modular Panels to suits user requirements.
- Typical modules are high pressure section with liquid booster to 6000 psi.
- Compound section for +/-1 bar with measure and control
- Low differential pressure section +/-10kPa with measure and control, pressure controller section for -1 to 20 bar.
- Multi -Function Calibrator
- Decade boxes and etc.
- For more information or customization, please contact factory.
Electric Pump Pressure Calibrator
EPC300
Portable Electric Pump Pressure Calibrator
Pressure Specification
Internal Reference Ranges | Â -95~3000kPa, -95~2000kPa, -95~1000kPa, -95~700kPa, -95~200kPa |
Accuracy | Â 0.025%FS (optional Dual Range, 50% F.S or 0.01%FS) |
Pressure Resolution | Â 6 Full Digits |
Temperature Compensation | Â 0 to 50 Deg C to rated accuracy |
Selectable Engineering Units | Â Mpa, bar, kg/cm2, kPa, psi, inH20(20/4 C), mmH20(20/4 C), inHg |
Time Pressure Generation | Â 0-20 bar < 45 seconds, 0-30 bar < 90 seconds, 0 to -0.95 bar < 5 seconds |
Control Stability | Â +/-0.0005 bar (using manual fine regulator) |
Pressure Generation | Â Built-in eletric pump (self generate), Maximum 30 bar |
Optional Electrical Inputs Â
mA Input Range | Â +/- 0 to 24 mA (Switchable internal 24 VDC@55 mA Loop Power) |
mA Input Accuracy | Â 0.015%FS |
mA Resolution | Â 0.001mA |
Volts Input Range | Â +/- 0 to 30 VDC |
Volts Input Accuracy | Â 0.025%FS |
Vdc Resolution | Â 0.001Vdc |
Switch Input | Â Non-contact Input |
General Specification
Display | Â L.C.D 128 x 64 dots matrix (with switchable white back-light) |
Warm Up Time | Â 5 minutes |
Communication | Â RS232 |
Optional Vacuum | Â Up to -99 kPa |
Power/Operating Hours | Â 14.8 V Li-ion / 4 hours per charge |
Unit Size | Â 315 x 255 x 150 mm |
Weight | Â 5 kg |
 Â
EPC600-Basic
Portable Electric Pump Pressure Calibrator
Pressure Specification  Â
Internal Reference Ranges | Â 0-7 bar, 0-20 bar, 0-40 bar, 0-70 bar, 0-100 bar |
Accuracy | Â 0.05%FS, 0.025%FS or 0.01%FS |
Pressure Resolution | Â 5 Full Digits (0.05% / 0.025%FS), 6 Full Digits (0.01% FS) |
Temperature Compensation | Â 0 to 50 Deg C to rated accuracy |
Selectable Engineering Units |
 Mpa, Bar, kg/cm2, kPa, psi, etc |
Time Pressure Generation | Â 0-7 bar (<1 min), 0-20 bar (<2 mins), 0-40 bar (<3 mins) |
Control Stability | Â +/-0.001 bar (using manual fine regulator) |
Pressure Generation | Built-in eletric pump (self generate), Maximum 40 bar Optional 70 Bar & 100 Bar |
Optional Electrical Inputs
mA Input Range | Â 0 to 24 mA (24 VDC Loop Power) |
mA Input Accuracy | Â 0.015%FS |
Volts Input Range | Â 0 to 30 VDC |
Volts Input Accuracy |
 0.025%FS |
Switch Input |
Non-contact Input |
General Specification
Warm Up Time | Â 5 minutes |
Communication | Â RS232 |
Optional Software | Â Easy Cal (for Pressure Gauge Calibration) |
Optional Vacuum | Â Up to -0.9 Bar or -0.99 Bar |
Size |  400 x 330 x 170 mm (for <=40 Bar) l 470 x 357 x 176 mm (for >40 Bar) |
Weight |  10 kg (for <=40 Bar)                       l 12 kg (for >40 Bar) |
Power/Operating Hours |
 14.8 V Li-ion / 3 hours per charge |
EPC600-Plus
Electric Pump Pressure Calibrator
Pressure Specification
Internal Reference Ranges | Â 0-7 bar, 0-20 bar, 0-40 bar, 0-70 bar, 0-100 bar |
Accuracy | Â 0.05%FS, 0.025%FS or 0.01%FS |
Pressure Resolution | Â 5 Full Digits (0.05% / 0.025%FS), 6 Full Digits (0.01% FS) |
Temperature Compensation | Â 0 to 50 Deg C to rated accuracy |
Selectable Engineering Units |
 Mpa, Bar, kg/cm2, kPa, psi, etc |
Time Pressure Generation | Â 0-7 bar (<1 min), 0-20 bar (<2 mins), 0-40 bar (<3 mins) |
Control Stability | Â +/-0.001 bar (using manual fine regulator) |
Pressure Generation | Â Built-in eletric pump (self generate), Maximum 40 bar Optional 70 Bar & 100 Bar |
Optional Electrical Inputs
mA Input Range | Â 0 to 24 mA (24 VDC Loop Power) |
mA Input Accuracy | Â 0.015%FS |
Volts Input Range | Â 0 to 30 VDC |
Volts Input Accuracy |
 0.025%FS |
Switch Input | Â Non-contact Input |
General Specification
Display | Â 4.3″ TFT Colour Touch Screen |
Warm Up Time | Â 5 minutes |
Communication | Â RS232 |
Optional Software | Â Easy Cal (for Pressure Gauge Calibration) |
Optional Vacuum | Â Up to -0.9 Bar or -0.99 Bar |
Size |  400 x 330 x 170 mm (for <=40 Bar) l 470 x 357 x 176 mm (for >40 Bar) |
Weight |  10 kg (for <=40 Bar)     l 12 kg (for >40 Bar) |
Power/Operating Hours |
 14.8 V Li-ion / 3 hours per charge |
EPC600-H
Electric Hydraulic Pump Pressure Calibrator
Pressure Specification
Pressure Range |
 0~100 bar, 0~200 bar,
 0~400 bar, 0~700 bar
|
Accuracy | Â 0.05 %FS, 0.025%FSÂ or 0.01%FS |
Resolution | Â 5 or 6 Digits |
Engineering Units | Â Mpa, kPa, bar, kg/cm, psi |
Pressure Stability | Â +/- 0.001 bar |
Operating Temperature | Â 0 to 50 Deg C |
Electrical Specifications
mA Range / Accuracy | Â 0 – 24 mA Loop Powered (without 24 Vdc) / 0.015%FS |
Volt Range / Accuracy | Â 0 – 30Vdc / 0.025%FS |
Pressure Switch |  Non Contact Input |
Basic Unit
Display | Â 4.3″ TFT Colour Touch Screen |
Warm Up | Â 5 minutes |
Communications | Â RS232 |
Software (Optional) |
 PC based TIS Integrated Calibration Software
 TIS Cal-Ware
|
Dimension / Weight | Â 400 x 330 x 170 mm /Â 10 kg |
TEMPERATURE CALIBRATION SYSTEM ATCS1200
ATCS1200
Technical Information
Temperature Range |
Ambient to 1200 Deg C |
|
 TC |  RTD | |
System Accuracy |  +/-1.0 Deg C (300 Deg C – 1200 Deg C) |  +/-0.5 Deg C (0 Deg  C – 300 Deg C) |
Scanner Accuracy | Â +/-0.4 | Â +/-0.25 |
Resolution | Â 0.1 Deg C | Â 0.1 Deg C |
Stability (20 to 30mins after normal stablisation) | ||
  Water Bath |  +/-0.01 Deg C | |
  Silicon Oil Bath |  +/-0.01 Deg C | |
  Furnace |  +/-0.5 Deg C (Probes & Reference should be tied together & insertion depth about 300mm) | |
Temperature Uniformity | ||
  Water Bath |  +/-0.05 Deg C | |
  Silicon Oil Bath |  +/-0.05 Deg C | |
  Furnace |  +/-0.5 Deg C (Same depth) | |
Working Volume   l Dimension  l  Weight | ||
  Water Bath |  Diameter: 75mm x 300mm  l  360 x 300 x 300mm  l 20kg | |
  Silicon Oil Bath |  Diameter: 75mm x 300mm  l  220 x 460 x 610mm  l 20kg | |
  Furnace |
 Diameter: 65mm x 300mm l 525 x 360 x  775mm  l 32kg |
Standard Accessories:
1) Factory Calibration Certificate for Scanner & Reference Probe tracable to National Standard
2) Operating Manual
3) TIS Temp. Cal-ware (software)
4) PT100 Class A Reference Probe (*For Model ATCS1200-W-S)
5) Typed S Class A Reference Probe (*For Model ATCS1200-F)
6) Type J,K,T,E extension wires x 12 pieces (2m each)
7) PT100 extension 4-wires x 12 pieces (2m each)
8) Power Cord
TACHOMETER CALIBRATOR RPM SERIES
Specifications of RPM Series | |
Speed/Velocity Contact | Â 0-6000 rpm / 0-12,000 rpm |
Speed/Velocity Non-Contact | Â 0-60,000 rpm / 0-100,000 rpm |
Uncertainties | Â +/-0.1 rpm below 1000 rpm, +/-1.0 rpm above 1000 rpm |
Resolution | Â 0.1 rpm (<1000 rpm), 1 rpm (>=1000 rpm) |
Shaft Rotation | Â Clockwise or Anti-Clockwise |
Stable Time | Â < 5 seconds |
Motor Type |  Ultra-Stable Servo Motor, 4000 counts encoder/Controller Direct Drive Shaft      (without gear) |
Noise Level @ 1 meter | Â < 50 dB |
Supply | Â 240 VAC, 50/60Hz @ 4 Amp |
Display | Â 4.3″ TFT Colour Touch Screen |
Unit Size | Â 420 x 350 x 250 mm |
Weight | Â 12 kg |
FIELD BUS POWER SUPPLY TIS-FBPS
TIS FBPS
Field Bus Power | |
Battery operated to output 24VDC to Power Transmitter or Valves Impedance Matching for Field Bus | |
Able to power up 1 segment Field Bus device | |
Can be configure to power up H.A.R.T. device, with impedance matching |